Airflow ManagementHorizontal Blanking Panels AisleLok® Under Rack Panels → Product Details


AisleLok® Magnetic Under Rack Panels

Applications

The Magnetic Under Rack Panel is a quick and easy way to improve airflow management by either blocking bypassairflowor exhaust air recirculation. It employs a unique sealing technology which allows easy, toolless modifications for just the right placement and height. It’s a perfect complement to existing blanking panels and accommodates thermal efficiencies in the data center.

Easily and quickly remove excess material for a custom height using the pre-scored lines on the back of the Under Rack Panel - without tools. The panel attaches magnetically for easy application and relocation. The AisleLok Magnetic Under Rack Panel comes in two sizes: 26" (660 mm) for rack width surfaces up to 24" W (610 mm) and 33.5" (851 mm) for rack width surfaces up to 31.5"W (800 mm)

The new AiseLok Magnetic Under Rack Panel will improve airflow management and help you recover stranded capacity. These panels are a cost effective way of reducing IT equipment hot spots, cooling unit inefficiencies, and infrastructure costs. Sealing the space under racks with the Magnetic Under Rack Panel is an essential aspect of airflow management best practices.

10226 26″ (660 mm) Magnetic Under Rack Panel

10227 33.5″ (851 mm) Magnetic Under Rack Panel

Features

Pre-scored lines
on the back of the panel

Removal of excess material
on the pre-scored line

  • Available in two widths; 26" (660 mm) and 33.5" (851 mm)
  • Prescored at 1-inch increments
  • Magnetic application
  • Rigid PVC material with UL94 HB
  • Economical solution
  • Compliant with directive 2002/95/EC of the European Parliament and the Council on the Restrictions of the Use of Certain hazardous substances in Electrical and Electrical Equipment (RoHS).

Benefits

  • Easily install, remove, and relocate with magnetic application
  • Toolless installation and height adjustment reduces overall install time
  • Effective seal blocks bypass airflow and or exhaust recirculation and resulting hotspots
  • Improves IT equipment reliability and extends equipment life
  • Supports cooling unit fan speed reduction
  • Supports higher supply air temperatures and free cooling utilization

Download the Special Technical Report from Upsite Technologies, Inc.:
Sealing Gaps Under IT Racks: CFD Analysis Reveals Significant Savings Potential

Specifications

Magnetic Under Rack Panel Description Dimensions Quantity per Carton Shipping Weight
Item No. 10226 26" Magnetic Under Rack Panel 26" x 4.75" x .06"
660mm x 121mm x 1.5mm
10 7 lbs.
Item No. 10227 33.5" Magnetic Under Rack Panel 33.5" x 4.75" x .06"
851mm x 121mm x 1.5mm
10 8 lbs.

 

PDFMagnetic Under Rack Panel - Models #10226, #10227 Data Sheet

Installation

AisleLok Magnetic Under Rack Panel InstallationThe AisleLok® Magnetic Under Rack Panel fits standard racks, up to 24"W or 31.5"W and is designed to minimize airflow underneath the rack. Before attaching the Magnetic Under Rack Panel, align the Panel with the rack to ensure proper fit location before installation. If required, remove the excess blade material by simply tearing it off by hand in 1" increments.

  1. Measure the distance from the bottom of the cabinet to the floor.
  2. Determine how long the Under Rack Panel needs to be and remove the excess blade material by tearing each 1" section by hand.
  3. Attach the Under Rack Panel to a flat surface on the bottom face of the rack.
  4. During installation allow for a 1" overlap between adjacent racks for a better seal.

The Magnetic Under Rack Panel should rest flush on the tile, with no gaps, to minimize airflow underneath the rack. When installed, the Magnetic Under Rack Panel may create an overlap up to 1" on the adjacent racks. The overlap is an intentional design, specifically blocking the bypass airflow between the adjacent server cabinets. The Magnetic Under Rack Panel located at the end of the aisle will need to be trimmed back so the overlap is not protruding.

Installation Note: The Magnetic Under Rack Panels are designed specifically for 24" W or 31.5" W racks. When installed on other rack widths the product label may not be centered with the rack/cabinet door.


Maintaining Proper Cooling of Equipment

Failure to follow computer manufacturer’s guidelines for maintaining proper cooling may result in the overheating of equipment. Before minimizing under rack airflow, ensure that proper airflow to the intake side of computer equipment or cabinets is feasible through the use of devices such as perforated floor tiles. Achieving proper airflow to the intake side of computer equipment and/or cabinets is the responsibility of the customer.

PDFMagnetic Under Rack Panel - Models #10226, #10227 Installation Guide

Contact your local Data Clean account manager for more information.

Back to Top